The solution I retained is to write DSRs in tagged-object format, i.e. the DF80 files produced by the TI assembler. A special loader, modeled on the one in the E/A cartridge, will be available for the user to load the required DF80 file into the DSR memory. Yes it's slower, but so is burning EEPROMs, and it's something the user won't do too often anyhow.
Another problem is that, even though the Flash-Memory is 8 megabytes in size (or 4 megs if you were cheap) , it maps at >4000-4FFF, so a page is only 4K. If a programmer needs more space, there should be a way to split the DSRs into several pages. However, the page numbers won't be available at programming time, because they depend on the order in which the user will load his DSRs.
The solution is easy: segment programming. The TI assembler carries all the necessary commands to this end, but we never used them because the TI loader doesn't handle them. Our special DSR loader does these commands and can dispatch segments between pages and link them together.
The present page explains how to write DSRs so that they can be handled by a common USB-DSR loader. It also describes several sets of low-level routines used to access the most basic features: Smartmedia, USB controller and memory. For specifics on how to program the various chips on the USB-SM card, refer to this page.
Writing DSRs
Using the SRAM
Standard memory routines
ISP1161 access routines
SmartMedia access routines
One usefull thing to do is to include a "COPY DSK1.USB/EQU" at the top of your file. This will include a definition file in your program, which contains a whole buch of EQUates and DEfines that will be usefull later. It will save you the burden of typing these DEFs on top of each of your programs.
To write distinct segments with the TI assembler, all you have to do
is to enclosed your code in between CSEG and CEND:
CSEG 'MYSEG ' ... your code CEND |
In the example above, MYSEG is the name of the segment.
There are a few special cases:
BLWP @SGBL DATA THERE,PG4SEG |
Where SGBL is the routine within the stub that switches pages and performs a BL to the specified address. PG4SEG is a dummy label which the loader will replace with the number of the page where THERE has been loaded.
To return to the caller, rather than doing a simple RT, the routine
THERE should call:
BLWP @SGRT |
Similarly, SGBLWP and SGRTWP are used to call and return from routines
requiring a context switch. Simple enough, no?
At power-up time, SRAM page 0 is selected, and every DSR that changes
this is supposed to switch back to page 0 upon leaving. So you can safely
place your workspace and data in this page. This is simply done by placing
all your variabled in the default data segment, i.e. by enclosing them
between a DSEG and a DEND command. Just remember that the SRAM is not battery-backed,
so you should not expect your variables to be initialized.
DSEG no segment name allowed with DSEG DATBEG DATA 0 your variables (not initialized) THIS DATA 0,0,0 TEST TEXT '.........' ... DEND |
As for your workspace, there are nine hierarchically arranged workspaces in page 0, termed L1WS through L9WS, which you are free to use. To do so, simply copy the file USB/EQU into your source file, it contains a bunch of EQU statments, among which those defining the workspaces.
If you need more memory, you can call the exported subroutine MALLOC to obtain a pointer to a buffer located in another SRAM page. This pointer can then be passed to the MCOPY subroutine to copy memory to or from this buffer, or even from one buffer to another. Contrarily to SRAM page 0, MALLOC-allocated buffers are private to your program and will not be shared by other DSRs. So you can use such a buffer to retain data in between calls to your DSRs. All you need to save (and retrieve) is a pointer to your buffer, which can be done with the TOSLOT and ATSLOT subroutines, respectively.
Alternatively, you can switch to a different SRAM page, the number of
which can be determined at loading time, or at run time. Switching is achieved
with either the RAMPG or the NEWWS subroutine, depending wether your current
workspace is in the SRAM or not.
Jumping pages
Fetching inline data
Shorter syntax
Segment flags
Entry segment
Info segment
Export segment
Stub segment
No-name segment
Segment order
EEPROM structure
To call a routine that you would normally enter with BL, do:
BLWP @SGBL DATA THERE DATA PG4SEG |
The first data word contains the address of the routine you want to call .
The second data word should contain the desired page number. As you don't know this at assembly time, it is better to replace it with the pseudo-label PG4SEG, which instructs the loader to use the page number for the routine that immediately follows.
SGBL saves the return address in R11, and the current page number in
R10. You must preserve both registers to properly return to the caller.
The return is achieved by calling:
BLWP @SGRT |
which performs the equivalent of an RT (i.e. B *R11), after switching
back to the page specified in R10.
To call a routine that you would normally enter with BLWP, do:
BLWP @SGBLWP DATA FOOBAR DATA PG4SEG |
The first data word should be the address (in the destination page) of the BLWP vectors: workspace and start address.
The second data word should contain the desired page number. As you don't know this at assembly time, it is better to replace it with the pseudo-label PG4SEG, which instructs the loader to use the page number for the routine that immediately follows.
SGBLWP saves the workspace in R13, the return address in R14, the status
in R15 and the current page number in R10. To properly return to the caller,
you must also preserve R10. Then simply call the SGRTWP routine, which
performs the moral equivalent of a RTWP, after switching to the page found
in R10:
BLWP @SGRTWP |
The trouble with BL is that you must preserve R11 before you can take another BL from within the called procedure. If you find this annoying, you're probably not too entranced at the idea of having to preserve yet another register, R10. In this case, SGBLX is for you!
The SGBLX routine works just like SGBL, except that it saves R10 and R11 in an internal stack, so you don't have to worry about preserving these registers. To return to the caller, just use SGRTX instead of SGRT. In fact, unpon entering the target routine, R11 will point at a BLWP @SGRTX instruction, so you can return with B *R11 if you want to.
Please note that the internal stack is circular and 8-level deep. Which means that if you nest 9 calls, unlikely as it is, the return parameters for the nineth call will ovewrite those of the first call. Also, the stack is located in the current SRAM page: if you switch RAM pages you will loose all return points.
Because R11 does not contain the return address, you cannot manipulate
it to change the return point. If all you need to do is to skip a jump
upon return, you can use ATR11X as discusse later. Otherwise, you'd need
to change the return point inside the stack, which is a bit complicated.
Your best bet is probably to pop the return parameters off the satck, and
to return directly to the desired address with SGB. This strategy is illustrated
below:
REF STAKPT THERE ... DEC @STAKPT decrement stack pointer SZCB @HFFE3,@STAKPT round to lowest multiple of 4, circularize BLWP @SGB "return" by branching to the point we want DATA ALTERN,PG4SEG HFFE3 DATA >FFE3 |
STAKPT is a number from >0000 to >001C which keeps track of the current entry in the stack. When it reaches zero, it rolls over to >001C and conversely. Thus the SZCB @HFFE3, which is the same as an ANDI >001C.
BL @THIS DATA >1234,THAT |
The routine THIS can then recover the data with two MOV *R11+,R0
instructions. A routine called with BLWP would do the same with MOV
*R14+,R0. Obviously, this is not going to work with routines located
in different pages! To solve this problem, you can use the routines ATR11
and ATR14.
BLWP @ATR11 or BLWP @ATR14 MOV R0,... MOV R0,... |
Each routine returns with R0 containing one word of data fetched from
the page specified in R10, at the address specified in R11 or R14, respectively.
The relevant register (R11 or R14) is incremented by two, so you can call
the routine again, if more than one word of data needs to be fetched. Make
sure you fetch all data words before returning to the caller. If you need
to retrieve inline parameters in a routine called with SGBLX use ATR11X
instead of ATR11.
BLWP @SGBLX call procedure THAT, saving R10 and R11 DATA THAT,PG4SEG JMP THERE * In another segment: THERE ... BLWP @ATR11X skip the JMP upon return BLWP @SGRTX or B *R11, if R11 was conserved |
A more general routine, is GETDAT (as a matter of fact, ATR11 and ATR14
are just different entry point into GETDAT). It is probably of little use
since most of your data will be in SRAM anyhow, but it may be used to fetch
a constant, for instance an entry from a pointer table.
LI R1,MYDATA MOV @MYPAGE,R2 BLWP @GETDAT MOV R0,... |
GETDAT retrieves data from the EEPROM page specified in R2, at the address specified in R1. One word of data is fetched and returned in R0. R1 and R2 remain unchanged.
A convenient way to obtain the page number for R2, is to take it from
a data structure containing the pseudo-label PG4SEG:
MYPAGE DATA MYDATA,PG4SEG |
The loader will replace PG4SEG with the number of the page where the label MYDATA is located. Note that you don't need to use the very same label as for the call to GETDAT, as long as it's located in the same segment.
* Relay call to export TOSLOT TOSLT1 DATA L1WR,TOSLT2 vectors for BLWP TOSLT2 BLWP @SGB call the routine DATA TOSLOT,PG4SEG * Now, instead of writing... BLWP @SGBLWP DATA TOSLOT,PG4SEG DATA MYSLOT * ...you can use the shorter form: BLWP @TOSLT1 DATA MYSLOT |
This saves you 2 memory words per call, with a one-time overhead of
5 words. So it's worth using if you have more than 2 calls to the same
procedure. It also makes your program easier to read. Yes, it is a bit
slower (using two cascading BLWP instead of one), but this is neglectable
compared with the amount of time it takes for SGBLWP to switch pages, retrieve
the vectors, and perform the actual branch...
NEWPG EQU >0001 ENDPG EQU >0002 FULLPG EQU >0003 MYPG EQU >0004 NOSTUB EQU >0008 MYSTUB EQU >0010 NOLINK EQU >0080NEWPG This flag causes the segment to be loaded at a fresh ROM page, which does not contain any other segment yet. If room is left after the segment is loaded, another segment (from you file, or from another DSR) may be loaded in the same page later on.
ENDPG This flag reserves the remainder of the page for your segment. It ensures nothing will be loaded after it, neither from your file, nor from subsequent loading sessions.
FULLPG This flag reserves the full page for your segment. As you may have noticed, it's actually a combination of NEWPG and ENDPG: so it starts with a fresh page, and no other segment will be loaded in the same page.
MYPG This is a somewhat mitigated version of NEWPG: your segment will be loaded into a page that is currently empty (from previous loading sessions) but into which other segments of yours may have been assigned. In other words, your segment won't mingle with segments from another DSR, but may cohabitate with some other segment of yours.
NOSTUB This flag relieves the loader from the obligation inserting a stub at the beginning of the page your segment is loaded in. Such a segment can be loaded in a page containing any stub, or no stub at all (e.g. if it's an empty page).
MYSTUB This flag informs the loader that it should use your own stub instead of the default one. Your stub must be in a segment called MYSTUB. If this segment is not found, the loader will use its default stub, or no stub a all if the NOSTUB flag is also set (MYSTUB has priority over NOSTUB). Again, only segments with the MYSTUB flag will be loaded together in the same page.
NOLINK prevents the loader from incorporating the segments within
a chained list. Normally, each segment is preceded with one word of data,
a pointer to the next segment (or free space). To find available space,
the loader walks this chain starting at >4000. If you don't want such a
structure to be installed, e.g. because you need to place your own data
at >4000, or because your segment is exactly 4K, you can set the NOLINK
flag. Be aware that it will make that page unavailable for loading further
segments, from other DSR files.
Lets now discuss the various special segments one at a time:
Entry segment
Info segment
Export segment
Stub segment
No-name segment
To create an entry segment, just include its code in a segment called 'ENTRY'. Note that the loader won't necessarily load this segment as such, but may perform some code manipulation (e.g. linking to other DSRs, etc).
Important: If the entry segment uses any REF label that is also used by other segments, then the entry segment should appear before those in your file.
There are four type of routines that can be found in typical DSR space:
Parameters are passed via a structure called PAB (peripheral access block, see this page for details) located in VDP memory. The first byte of the PAB indicates the type of operation desired: open, close, read, write, restore, load, save, delete, scratch-record, or file status. According to the operation, parameters such as file type, opening mode, or file data will be passed to the DSR through the PAB. See this page for more information.
Another way to pass parameters to a DSR is to include them after the DSR name, using a dot as a separator. A well known example is the RS232 DSR which can be called with something like "RS232.BA=9600.DA=8.CR.LF". The DSR name is "RS232", the rest are parameters interpreted by the DSR.
Be aware that each time a file operation occurs, all DSRs on all cards will be scanned until the proper name is found. Thus, try to avoid multiplying DSR names, since it may slow the system. Also, remember that there is limited space in page 0 that should accomodate all DSR and subprogram names for the USB-SM card. It is thus best to have a main DSR and split it by the way of parameters. For instance, the USB controller can handle 127 devices, so you may want to create 127 DSRs called "USB1" through "USB127". This wouldn't be a good idea. It's much better to use something like "USB.1" where there is only one DSR (called USB) and the device number is passed after the dot.
You tell the loader that you wish to declare DSRs by defining the label MYDSR. Since you can have more than one DSR, you should arrange them as a chain and have MYDSR point to the first link in the chain. Each link consists in two data words (aligned on word boundaries!): the address of the next link, and the address of the entry point. These are followed with the DSR name, which should be a string from 1 to 7 characters, with a leading size byte. The last DSR in the chain will have >0000 in its link field.
To save space in page 0, a DSR entry point should consist only of a branch order to the page where your DSRs are loaded. You can use the routine SGB to this end, but not SGBL nor SGBLWP as these routines are not present in page 0.Your target routinewill be entered with whatever workspace the calling program is using (>83E0 from Basic and Extended Basic, anything from assembly). You can expect R12 to contain the card DSR, and R11 to contain the return point. Make sure you preseve R11 when returning from your DSR. In addition, R1 should contain the number of times this DSR was already found, a feature used by DSRs that can be present on multiple cards. You don't have to preserve R1 if your DSR doesn't use this feature.
Once done, you should increment R11 by two and return by branching to PG0RT (this is number zero, not letter o). This routine simply switches back to page 0, restores R12, and performs a B *R11. Optionally, you can dispense with INCTing R11. In this case, the calling routine will keep searching for DSRs with the same name. For this to work properly, you should preserve R1 as well as R11.
Example of DSR entry points:
DEF MYDSR REF SGB,PG0RT,PG4SEG *---------------------------------- * No-name segment: loaded in page 0 *---------------------------------- CSEG MYDSR DATA LK2 link to next DSR DATA ENT1 entry point for this one BYTE 4 size byte TEXT 'DSR1' DSR name EVEN word-align (important!) LK2 DATA LK3 DATA ENT2 BYTE 3 TEXT 'FOO' EVEN LK3 DATA 0 no more links DATA ENT3 BYTE 3 TEXT 'BAR' EVEN * ENT1 BLWP @SGB entry point for 'DSR1' DATA MYDSR1 address DATA PG4SEG let loader provide the page # ENT2 BLWP @SGB entry point for 'FOO' DATA FOODSR,PG4SEG ENT3 BLWP @SGB entry point for 'BAR' DATA BARDSR,PG4SEG CEND *---------------------------------- * Our first segment: loaded wherever it fits *---------------------------------- CSEG MYSEG1 MYDSR1 ... code for 'DSR1' SK1 INCT R11 no more scanning BLWP @PG0RT return to page 0 and do B *R11 FOODSR ... code for 'FOO' JMP SK1 return as above BARDSR ... code for 'BAR' JMP SK1 return as above CEND END |
A big difference with DSRs is in the way parameters are passed, as there is no PAB. For subprograms called from Basic, you must parse the Basic statement to find parameters in the parenthesis following CALL. This is quite tricky to do, as numeric parameters can be passed via complicated math expressions, and string parameters can include things like SEG$ and CHR$. The situation is much simpler in assembly, where parameters are generally passed in CPU memory, at address >834A and above.
It is possible to append parameters to the subprogram name (e.g. CALL MYSUB.A=1.NOLOAD) but be aware that these long names may not be properly saved within a Basic program, so it's only usefull for subprograms called interactively, from the keyboard.
Your subprogram will be entered with the caller's workspace, and you can expect R12 to contain the card's CRU. Do not loose R11, since it contains the return point. Just like with DSRs, R1 can optionally contain the number of times this particular subprogram name was found.
Once your subprogram is done, it should increment R11 by two and return with B @PG0RT, which returns to page 0 and performs a B *R11. Optionally, you can dispense with incrementing R11, which will cause the scanning routine to keep searching cards for subprogram with that name. In this case, make sure you also preserve R1.
Since you might want to define more than one subprogram, you should always arrange them in a chain (even if there is only one). Then define the label MYCALL, and have it point to the first link in the chain. The structure of the chain is the same as for DSRs.
Here is an example:
DEF MYCALL REF SGB,PG0RT,PG4SEG *---------------------------------- * No-name segment: loaded in page 0 *---------------------------------- CSEG MYCALL DATA LK2 link to next subprogram DATA ENT1 entry point for this one BYTE 4 size byte TEXT 'THIS' subprogram name EVEN word-align (important!) LK2 DATA 0 no more links DATA ENT2 BYTE 4 TEXT 'THAT' EVEN * ENT1 BLWP @SGB entry point for 'THIS' DATA THIS1 address DATA PG4SEG let loader provide the page # ENT2 BLWP @SGB entry point for 'THAT' DATA THAT1,PG4SEG CEND *---------------------------------- * Our first segment: loaded wherever it fits *---------------------------------- CSEG MYSEG1 THIS1 ... code for 'THIS' SK1 INCT R11 no more scanning BLWP @PG0RT return to page 0 and do B *R11 THAT1 ... code for 'FOO' JMP SK1 return as above CEND END |
Be carefull that, no matter what type of reset occured, only one type of power-up routine will be called. Generally, you should write your power-up routine in a cascading fashion, with three entry points:
PEBOX ... Entry point for PE-Box power-up ... Code unique to PE-box reset CONS ... Entry point for console power-up ... Code unique to console reset SOFT ... Entry point for software reset ... Code unique to software reset RTTo inform the loader that you intend to load a power-up routine, you should define the label MYPWUP in your program, and have it point at the first link of your power-up routine (even though there is no need for more than one routine, you could have several, therefore a chain structure is used, similar to the one we saw for DSRs, but without names). From there, you can either branch directly to the page in which your DSRs are loaded, or perform a quick test to determine which type of reset occurred. Before it calls your routine, the card's power-up routine will set a flag in R0 with the following values:
R0 = >FFFF for PE-box reset (test with JLT)
R0 = >0000 for console reset (test with JEQ)
R0 = >0001 for software reset (test with JGT)
N.B. The flag in placed in R0 just before entering your routine, so you don't need to add a MOV R0,R0 to test it.
Example of power-up entry point:
DEF MYPWUP REF SGB,USBRT,PG4SEG *---------------------------------- * No-name segment: loaded in page 0 *---------------------------------- CSEG MYPWUP DATA 0 no more links DATA MYP1 entry point MYP1 JEQ SK1 trap software reset (example) BLWP @SGB call our routine for others power-up types DATA MYPW1 address of our routine DATA PG4SEG let loader fill in page # SK1 B *R11 return doing nothing CEND *---------------------------------- * Our first segment: loaded wherever it fits *---------------------------------- CSEG MYSEG1 MYPW1 JLT SK2 trap console reset ... code for PE-box reset SK2 ... code for console reset BLWP @PG0RT return to page 0 CEND END |
In this example, a software reset necessitates no special action, so that kind of power-up is trapped immediately. The other two types of reset require special handling, so we are branching to our routine in another segment. Note the branching is performed by calling the routine SGB with two data words: the address and the page number. Since we don't know what the page number will be, we used the pseudo-label PG4SEG wich instructs the loader to provide the page number for the address found in the previous word (here MYPW1).
The routine is entered with the GPL workspace: >83E0. You can expect to find your card CRU in R12. The entry routine has saved R12 through R15 and will restore them once our routine returns.
Once done, your routine must call PG0RT, which switches back to page 0, and performs a RT. This returns to the USB entry routine, which will call power-up routines for others DSRs, if any.
To provide an ISR, you should define the label MYISR and have it point to the first link in your ISR chain. Again, even though there is generally only one ISR, a chain structure is provided in case you wanted to use more than one routine. Normally, the entry point will immediately branch to your ISR routine in another segment. However, you may want to first test CRU input bits 0 and 1, to determine whether the interrupt came from the USB host controller or from the USB device controller.
It is your responsability to determine whether the interrupt was generated by your device or by another one. If it's not your device, your routine should branch immediately to PG0RT, which will return to page 0 and call the ISRs for other DSRs. If the interrupt did come from your device, you must clear the interrupt condition and increment R11 by two before branching to PG0RT. This will prevent the stubs from calling further ISRs.
Again, the ISR is entered with workspace >83E0, and R12 should contain the card's CRU. The card's ISR routine has saved R12 through R15 and will restore them upon return from your ISR.
Example of ISR entry point:
DEF MYISR REF SGB,USBRT,PG4SEG *---------------------------------- * No-name segment: loaded in page 0 *---------------------------------- CSEG MYISR DATA 0 next link: no more DATA MYISR1 entry point MYISR1 TB 0 host controller interrupt? JNE SK1 no: don't do anything BLWP @SGB call our routine for host controller ints DATA MYISR2 address of our routine DATA PG4SEG let loader fill in page # SK1 B *R11 return doing nothing CEND *---------------------------------- * Our first segment: loaded wherever it fits *---------------------------------- CSEG MYSEG1 MYISR2 ... check if interrupt came from our device JNE NOTUS nope ... yes: handle it, clear interrupt INCT R11 no more ISR scanning NOTUS BLWP @PG0RT return to page 0 CEND END |
CSEG 'INFO ' TEXT 'USB-SM 1.5' device name BYTE >00 field separator TEXT 'Sample DSR. No real use.' one-line description BYTE >00 TEXT ' Sample DSR' full-screen description BYTE >0D next line TEXT ' ----------' underlining the title BYTE >0D,>0D skip 2 lines TEXT 'This is not really a DSR. It`s ' TEXT 'here to demonstrate the use of ' TEXT 'the INFO segment. ' BYTE 0 CEND no third field, here |
Each entry in the export segment has the following format:
Here is an example of such a segment:
CSEG 'EXPORT' TEXT 'VSBW ' DATA VSBW1 DATA PG4SEG TEXT 'DUMBOS' DATA DUMBOS DATA PG4SEG CEND |
Note that the DSR file exporting the routines must be loaded before
the one referencing to them. So there is no way you can have two DSR files
cross-referencing each other: you would get a 'label not found' error when
loading the first one.
To append code to the existing stub, just include it within a segment called STUB. The loader will add your code at the end of the default stub. To create your own stub, make up a segment called MYSTUB. You can have both a STUB and a MYSTUB segment in your program.
So that the loader knows which stub is to be used (if any) with each segment, you should set the proper segment flags (see below):
Important note: If your stub segment(s) contain any REF label
shared by another segment, the stub segment should appear last in your
file. If you're using both MYTSUB and STUB, then STUB should appear last.
DEF FOO,BAR CSEG FOO ... your routines BAR ... CEND |
For this to work, the no-name segment should be the first (possibly the only) segment in the file. Other programmers will load the file after one of theirs, and your segment will be appended to the end of the last segment in the previous file. By last segment, I mean the last that was started, not necessarily the last to finish (if you split your segments, which I do not recommend).
So what happens if the no-name segment is the first to be loaded? Nothing
exciting: it is just considered as a stand-alone segment, with the name
$BLANK.
If your file does include an EXPORT segment, only one copy of your routines will be present in the EEPROM. All DSRs loaded after yours can call your routines, but they must use page-jumping routines (e.g. SGBLWP), and this is quite slow. Only one DSR can use direct calls, the one that loaded your file initially.
In the end, it's up to you. If you expect other programmers to merge
your routine with one of their segments, you should probably not export
them, since it may cause name conflicts when different DSRs include your
routines. Other programmers can always make up an EXPORT segment if they
feel they need one. Alternatively, you could provide the EXPORT segment
on a separate file.
For the same reason, it's better if each segment is kept as a single block. You could chop them into pieces and interlace them, but that may prevent the loader from resolving all REF labels. The key here is that, if two segments uses the same REF label, then all occurences of this label should appear in the same order as the segment declarations.
CSEG 'SEG1' CSEG 'SEGA' CSEG 'MYSEG1' DATA ANYREF<-, DATA ANYREF<-, CEND ,->DATA ANYREF--' CEND | CSEG 'MYSEG2' | CEND CSEG 'SEGB' | DATA ANYREF<-, | CSEG 'SEG2' ,->DATA ANYREF--' ,->DATA ANYREF--' '--DATA ANYREF<-, | CEND | CEND CEND | | CSEG 'SEGA' | CSEG 'MYSEG1' CSEG 'SEG1' | '--DATA ANYREF<-, '--DATA ANYREF<-, CEND | CEND | CEND | REF ANYREF--' REF ANYREF--' REF ANYREF--' * This is ok * This won't work * Neither will thisBecause data within an EEPROM cannot be modified, the loader must build segments one at a time in the memory expansion, starting with the last one. More precisely: first STUB, then MYSTUB, then any other segments in reverse order of apparition, then the no-name entry segment (INFO and the data segments are never loaded).
It ensues that the loader cannot walk a REF chain if it goes through a segment that hasn't been loaded yet. In the second example above, the loader processes SEGB first, so it cannot walk the ANYREF chain through SEGA. And when SEGA is built, the loader cannot walk "through" SEGB to follow the links. A similar, less obvious, situation occurs in the rightmost example, where MYSEG2 is process first (because its CSEG appears after MYSEG1's), at a time when the REF chain hasn't yet been walked through MYSEG1.
In conclusion, to avoid that kind of problem, don't split your segments and arrange them as described above.
Each segment is preceeded with a pointer, i.e. a data word containing the next free address after the segment. This address may in turn contain a pointer to the next one, etc.
A4000 DATA PT1 Address >4000 .... First segment (generally STUB) PT1 DATA PT2 ... Second segment PT2 DATA >FFFF End-of-chain mark ... Third segment DATA >FFFF, FFFF,... Free spaceThe exception to this rule is page 0, in which address >4000 is needed for the standard ROM header. Thus, the first link in page 0 is located at >400E instead.
Other important locations in page 0 are:
Removal information is saved in the same manner. It begins with four data words: a pointer to the next chunk of removal info, the numbers of the last export before yours, and the number of your last export (if these numbers are identical, you defined no exports), and finally a pointer to a list exports REFed by your program.
Then it lists the page number, address, and size for each segment in your program. The list always begins with the data segment and the no-name entry segment, even if they were not used in your program.
Finally, the loader lists the ordinal number of each export used by a REF in your file. The list ends with a >8000 endmark. It has a maximum size of 256 entries, if your program REFed more exports than this, the endmark will contain the number of unlisted REFs, in the form >8xxx.
This information can be used by a DSR management program to safely remove a DSR file from memory. By comparing your export numbers with the REF lists of other DSRs, it can determine whether removing your DSR would compromise others. The segment table lets us determine which memory page can be reclaimed, and possibly erased, by removing your DSR.
Example of removal information:
A4000 DATA >5000 Reserve full page DATA >0002 Page number DATA PT1 Info for next DSR loaded DATA >0012 Number of the last export before ours DATA >0014 Number of our last export (i.e. we had two) DATA XP1 Pointer to list of REFed exports DATA >0000 SRAM page for DSEG segment DATA >5100 Address of DSEG segment DATA >0124 Size of DSEG DATA >0000 ROM page for entry segment (always 0) DATA >4530 Address of entry segment DATA >0064 Size of entry segment DATA >0042 Page where one of our segments is DATA >4106 Address of this segment DATA >0AFE Its size DATA >0025 Page number for another segment DATA >4804 Its address DATA >0106 Its size XP1 DATA >0003,>0017,>0025 List of exports REFed by our DSR DATA >8000 Endmark PT1 DATA >FFFF,>FFFF... Free space (or >0000,next_page)
One thing I must mention right away is that the SRAM is not battery
backed. This means that it will contain random data upon power-up. Thus,
you cannot initialize your data the way you would in a regular assembly
program (e.g. with DATA >1234 or TEXT 'TEST'). If you need to initialize
variables, you must do it programmatically, for instance by having the
initial values in the EEPROM and copying them into the SRAM when needed.
Here is an example:
*---------------------------------- * Code segment: in EEPROM *---------------------------------- CSEG 'FOOBAR' INIVAR LI R0,ROMVAR optional: init variables LI R1,HITS LI R2,VAREND-ROMVAR LP1 MOVB *R0+,*R1+ copy ROM to RAM DEC R2 JNE LP1 ... DUMMY MOVB @HERE,@THERE use variables (dummy example) DEC @HITS LI R1,TITLE MOV @SIZE,R2 BLWP @VMBW ... ROMVAR DATA 5 initial values to be copied in RAM BYTE >AA BYTE >55 DATA 14 TEXT 'This is a test' VAREND CDEND * *---------------------------------- * Data segment (assigned to SRAM) *---------------------------------- DSEG HITS DATA 0 our variables HERE BYTE 0 THERE BYTE 0 SIZE DATA 0 TITLE BSS 14 DEND |
There are several ways to use the SRAM, so as to avoid conflicts with other DSRs:
Workspace issues
Data segment DSEG
MALLOC and MCOPY
Private memory slot
Private data segments
Switching pages
Data segment flags
SRAM internal structure
As a result, you're probably better off switching to a dedicated workspace,
located inside the SRAM. This is best done with a BLWP, so you can return
to the original workspace with a simple RTWP when done. A slightly more
sophisticated way is to use the following trick:
BLWP @MYWS Trick to change workspace and continue below ... Your DSR code BL @OLDWS Trick to retrieve old workspace INCT R11 Return with no error (example) B *R11 Exit DSR * MYWS DATA WREGS,HERE Vectors HERE B *R14 Return with new workspace * OLDWS MOV R11,R14 Copy return point RTWP Return with old workspace |
The only question is, where to place your new workspace?
SRAM page 0, which should be on by default when your DSR is entered, has space for 9 workspaces, arranged in a hierarchical fashion. If you COPY the file USB/EQU into your own, you will be able to call them by name, from L1WS (>5FD0) to L9WS (>5ED0).
The simple rule to follow is that a subroutine that doesn't BLWP to another routine should use the level 1 workspace, L1WS. A routine that calls one or more level 1 routines should use the level 2 workspace L2WS. As so on, upto level 9.
If you export one of your routines for use by other DSRs, make sure
to document which level workspace it uses. Here also, the key is that any
routine that wants to call that one should do it from a workspace at least
one level above.
To use the default data segment, just enclose your variables between a DSEG and a DEND statements, similar to what you have been doing for code segments with CSEG and CEND. No segment name is needed, nor accepted, since the assembler supports only one data segment.
Remember that the default data segment (as well as the rest of SRAM page 0), is shared by all DSRs. So you should not expect any data to remain untouched in between two calls to your DSR. Also, if your DSR calls an exported routine, check the docs to see if this routine uses any data space in page 0 (and please make sure you include this info for any routine that you export).
MALLOC takes one argument in R0: the number of bytes you need. It returns with a page number in R0 and with an SRAM address in R1. The Eq bit will be set upon return if the memory could be allocated. If the Eq is not set (test it with JEQ or JNE) something went wrong. Very likely, you're running out of RAM pages, or you asked for too big a chunk (max size is a bit under 4 kbytes).
FREE takes two argument: the page number in R0 and in R1 the address of the first byte to free, both as received from MALLOC. It will free the number of bytes that were allocated when MALLOC was called.
Here's an example:
CSEG 'TEST ' LI R0,1024 reserve 1024 bytes BLWP @SGBLWP call routine in another segment DATA MALLOC,PG4SEG JNE ERROR trap errors ... use memory BLWP @SGBLWP (assuming R0 and R1 unchanged) DATA FREE,PG4SEG free the memory CEND |
MCOPY is a procedure that you can used once you obtained buffer space with MALLOC, to copy data to and from it. Its parameters are the following:
R0: source page
R1: source address
R2: number of bytes to copy
R3: destination page
R4: destination address
Obviously, R0 and R3 are only relevant if the corresponding address
is in the SRAM space, i.e. >5000-5FFF. Optionally, you can use >FFFF as
a page number to specify the current SRAM page. MCOPY also works to/from
VPD memory and GROM/GRAM, but more on this later.
MOV @MYPAGE,R0 from this page LI R1,MYDATA at this address LI R2,512 512 bytes SETO R3 into current page LI R4,MYBUF at this address BLWP @SGBLWP DATA RAMCPY,PG4SEG copy |
If you need a permanent memory area, you can obtain one with MALLOC: the allocated memory won't be touched unless you free it, or the computer is rebooted. However, you still have a problem: how do you remember the location of that memory area? This is where your private memory slot comes in.
By REFerencing the label MYSLOT, you will cause the loader to assign you a unique slot of 4 bytes in RAM page 1. The address of which will be provided in MYSLOT. Four bytes is not much, but it's enough to save the pointer returned by MALLOC. For this you can use the dedicated routines TOSLOT and ATSLOT.
TOSLOT saves R0 and R1 into your private slot. It must be followed with a data word containing a reference to MYSLOT.
ATSLOT retrieves the contents of your private slot into R0 and R1. The call must also be followed with MYSLOT. Upon power-up, you can expect your slot to contain >0000, >0000.
Here's an exemple of how to use this feature.
REF MYSLOT * This is performed upon power-up, or the first * time your DSR is entered: it reserves some memory for later LI 0,>0678 number of bytes required BLWP @SGBLWP DATA MALLOC,PG4SEG get private memory area JNE ERROR BLWP @SGBLWP DATA TOSLOT,PG4SEG save its location DATA MYSLOT data for TOSLOT * Any time your DSR is entered, it can find out * where the reserved memory is located BLWP @SGBLWP DATA ATSLOT,PG4SEG retrieve R0 and R1 DATA MYSLOT ... use them, for instance with MCOPY * This may be done once you don't need the memory any more BLWP @SGBLWP DATA ATSLOT,PG4SEG retrieve R0 and R1 DATA MYSLOT BLWP @SGBLWP DATA FREE,PG4SEG free our memory area CLR R0 CLR R1 BLWP @SGBLWP DATA TOSLOT,PG4SEG empty our slot DATA MYSLOT |
TOSLOT and ATSLOT are part of the same segment than MALLOC, in the file
STDMEM/O. See below for a complete description.
The remaining question is where to place private data segment(s). To prevent unused DSRs from hogging the SRAM, I decided that private data segment will not be given a preserved memory area. Instead, you'll need to reserve one the first time your DSR is called. There are three ways to do this, starting with the most convenient, but also the most likely to fail the SRAM gets full...
REF LOCKDS,MYDSEG CSEG 'TEST' ... BLWP @SGBLWP reserve our private area DATA LOCKDS,PG4SEG DATA MYDSEG,DATBEG,DATEND JNE ERROR make sure it did work JOC MAYBE already reserved (by us?) ... ok, we can switch to our page now CEND CSEG 'DATA01' private data segment DEF DATA01 DATA01 EQU DSEG+FIXPG setting segment flags DATBEG DATA 0 your first data word ... more data DATA 0 your last data word DATEND CEND |
You must check the Eq bit to find out whether LOCKDS failed. This may happen if the space you requested has already been allocated to another DSR by MALLOC. To make it as unlikely as possible, the loader allocates private segments from page 254 down, whereas MALLOC allocates buffers from page 2 on. But if the SRAM gets heavily used, it may happen. In this case, your DSR should return with a "memory full" error.
You may also want to test the carry bit; LOCKDS will set it if the area
you requested is already occupied by a buffer of the exact same size as
your data segment. Since it is very unlikely that MALLOC would have attributed
a buffer to another DSR with the exact page number, address, and size as
your data segment, it probably means that your DSR has already called LOCKDS.
But to make really sure, you may want to include a flag to this effect
inside your data segment, and test is with MCOPY...
REF LOCKDS BLWP @SGBLWP reserve our private area DATA LOCKDS,PG4SEG DATA DATBEG,DATEND no page number here JNE ERROR make sure it did work ... ok, we can switch to our page now * Free it when done MOV @>5002,R0 retrieve page number (assuming standard page) LI R1,DATBEG get address BLWP @SGBLWP free private area DATA FREE,PG4SEG |
Since SRAM page numbers are in the range 0-255, but SRAM addresses are >5000 or bigger, LOCKDS can easily detect that you did not provide a page number. It will then obtain one from MALLOC, sepcifying a fixed address (DATBEG in the example) and a size calculated by substracting DATBEG from DATEND. (As a matter of fact, LOCKDS is nothing more than a specialized entry point into MALLOC).
Again, you must make sure it did work, which is more likely to happen since MALLOC now has the choice between 253 pages instead of just one.
Note that you must have a way to make sure that your DSR has not been
entered before and already reserved a page, otherwise LOCKDS called in
this way will simply issue another page at each call. You may do this by
using the MYSLOT mechanism. Alternatively, you may free the allocated page
once your DSR is about to exit, as in the example above.
REF LOCKDS LI R0,DATEND-DATBEG size of our data segment BLWP @SGBLWP reserve our private area DATA MALLOC,PG4SEG JNE ERROR make sure it did work ... ok, switch to page in R0 * Fixing variable addresses: LI R2,DATBEG S R2,R1 calculate offset CLR @DATBEG(R1) index every data access LI R9,DATBEG immediate arguments cannot be indexed A R1,R9 so we need this to correct the address CLR *R9 |
However, we now have a huge problem to face: since the address of your data segment is not known at loading time, any code burnt into the EEPROM will reference variables at likely invalid addresses. For instance, assuming the loader placed your data segment at >5800, the statement CLR @DATBEG will be burnt as >04E0 >5800. But if MALLOC places your data segment anywhere else than >5800, the CLR statment will still clear address >5800 and likely wreck havoc with another DSR, or another part of your data. You need a way to correct the addresses of your variables, but since the EEPROM cannot easily be written to, you cannot patch your code. The solution is to modify your code by indexing every variable address. That is, write CLR @DATBEG(R1) instead, and make sure that R1 contains the offset between the actual and the intended address. See the example above (in real life, you may want to use a register other than R1 as an index, since R1 is often heavily used).
... assuming R0 just filled in by MALLOC or LOCKDS BLWP @RAMPG |
But things are trickier if you have already switched to a workspace
located in the SRAM (this may happen if you have more than one data segment).
By switching SRAM pages, you will loose your current workspace! One way
around this is to used NEWWS to switch pages and select a new workspace.
NEWWS is called with a pointer to the desired workspace in R0+R1, and the
number of bytes to copy as an inline data (32 to copy the entire workspace).
It will switch pages (to the page number in R0), copy your old workspace
onto the new one, and return control to you with the new workspace active.
... assuming R0 just filled in by MALLOC or LOCKDS LI R1,WREGS2 address of our workspace in private data segment BLWP @SGBLWP DATA NEWWS,PG4SEG DATA 32 number of bytes to copy from old workspace to new one |
DSEG EQU >8000 FIXPG EQU >0002 NOREG EQU >0004 NOSTUB EQU >0008 MYSTUB EQU >0010 NOLINK EQU >0080DSEG Indicates a data segment. This flag is set be default if the segment names begins with 'DATA' or with 'SRAM', as well as for the ndefault data segment produced by the DSEG directive.
FIXPG Instructs the loader to assign an SRAM page number for this segment. If the flag is not set, an invalid page number will be used, and the final page number must be obtained from MALLOC or LOCKDS at run time. This flag is set by default for segment with a name beginning in 'SRAM'.
NOSTUB The loader normally reserves the beginning of each SRAM page (upto >5040) for use by the page-switching routines found in the EEPROM code stubs. If you are not using these, you can start reclaim these extra bytes by setting the NOSTUB flag. This flag tells the loader that it is not necessary to reserve the first 64 bytes, but it does not actively prevent it. In other words, your segment will be assigned to a convenient page, no matter where the page starts at.
NOREGS The end of SRAM page zero is reserved for use by the nine hierarchically-arranged workspace (>5ED0-5FDF) and by the USB chip registers (>5FE0-5FFF, when CRU bit 1 is set). If your routine use one of these workspaces (or call routines that do), then it is wiser not to place anything else in that space. Thus, the loader considers that every SRAM page ends at >5xxx by default. You can revert this by setting the NOREGS flags, which allows to loader to map your data segment upto the very end of the SRAM page (>5FFF), if need to be.
MYSTUB This flag instructs the loader to use the two variables SRAMLO and SRAMHI at lower and higher address for a page where to place your data segment. If you set this flag, you must DEF these two labels and set their values with EQU statements.
NOLINK As outlined below, each SRAM page begins with a link word, installed at power-up time, that allows MALLOC to determine how much free or allocated space is on that page. This implies that data can only be mapped starting at >5002. If you insist on including word >5000, you can set the NOLINK flag. Be aware that you will need to set the >5000 to a value that cannot be mistaken for a link word, i.e. not in the range >5000-5FFF, nor >D000-DFFF.
For instance, every SRAM page should begin with the following stub:
>5000 DATA ENDSTU Point to next block DATA >0001 Page number DATA 0,1,2,3,4,5,6,7,8,9,10,11 Workspace for page switching routines (R0-R11) DATA >1D0A Address of CRU bit 5 (also R12) DATA 13,14,15 End of workspace (R13-R15) BSS 26 Reserved, 13 words ENDSTU DATA >5FFF+>8000 Free upto end of page (>5040-5FFF)N.B. In all pages, the area >5FF0-5FFF is only accessible when CRU bit 1 is '0', when this bit is '1' the USB controller maps there. In page 0, the area >5ED0-5FEF is used for the 9 default workspaces. If you intend to call these with another SRAM page on, you should make sure this area is available.
If you were to reserve 512 bytes with MALLOC, the pointer at ENDSTU would change as follows:
ENDSTU DATA NEWEND Point to next block FORYOU BSS 512 Space reserved for you NEWEND DATA >5FFF+>8000 Free to end of page
In this example, the address labelled FORYOU would be returned by
MALLOC in the R1 register.
Calling FREE will result in merging the NEWEND and ENDSTU pointers, reverting to the first example above.
Technical note: most of these routines are all "level 1" routines (i.e. do not call other exports), and use L1WS as their workspace. The exceptions being NEWWS and BURNW which use L2WS as their workspace. However, many of them use another worskspace in the scratch-pad, at >8300, so they can switch pages. The content of the scratch-pad is saved, and will be restored upon return. This means that you should not use MCOPY with an address in the range >8300-831E, nor in the range >5FD4-5FE2.
VSBR VDP Single Byte Read VMBR VDP Multiple Bytes Read VSBW VDP Single Byte Write VMBW VDP Multiple Bytes Write VIMW VDP Identical Bytes Write VWTR VDP Write To Register
BURNW Burn Word into Flash-EEPROM
MALLOC Memory Allocation in SRAM FREE Free previously allocated memory RAMCPY Copy to/from SRAM NEWWS Switch to a new workspace in SRAM, optionally copy from old one TOSLOT Save R0 and R1 into our private slot ATSLOT Retrieve R0 and R1 from our private slot LOCKDS Reserve SRAM space for a private data segment
Exemple:
REF VSBW LI R0,>0020 LI R1,'A ' BLWP @SGBLWP DATA VSBW,PG4SEG |
Note: Because these subroutines are located in a different segment, calling them takes MUCH more time than having your own VSBW inside of your segment. Thus, I'd recommend that you only call these subroutines if you really need to, i.e. if they make use of SRAM buffers.
Exemple:
REF VIBW CLR R0 start from >0000 LI R1,' ' fill with spaces LI R2,>0300 24 lines of 32 bytes BLWP @SGBLWP clear screen DATA VIBW,PG4SEG |
Exemple:
REF VWTR LI R0,>01F0 target: VDP register 1 BLWP @SGBLWP set text mode DATA VWTR,PG4SEG |
R0: EEPROM page number (0-7FF).
R1: Address in EEPROM memory (>4000-4FFF)
R2: Data word to write.
The routine returns its results in the status register. You can trap it with the following instructions:
JEQ All went well JNE Something went wrong JGT EEPROM complained of an error (e.g. write-protected) JLT Result doesn't match expected value (e.g. '0' bits can't become '1')Exemple:
REF BURNW LI R0,>0005 page 5 LI R1,>4822 target address LI R2,>1234 value to write BLWP @SGBLWP DATA BURNW,PG4SEG JNE ERROR trap errors |
R0: Number of bytes needed (max >2000). Upon return: SRAM page
number.
R1: Upon return: Address of the required memory.
Upon return, the Eq bit will be set if all went well. You can thus trap the result with the following instructions:
JEQ All went well JNE Error (e.g. memory full)See above for examples.
There are special ways of calling MALLOC, to force the choice of a given page, given address, or both. This is indicated by setting flags in R0:
Add >8000 to R0 to force MALLOC to return a buffer starting at a given
address. This address must be in R1 upon calling MALLOC
Add >4000 to R0 to force a given page. The page number must be in R2
upon calling MALLOC. It will be in R0 upon return, as usual.
Add >C000 to R0 to force a given address (in R1) and a given page (in
R2).
Be aware that the chances for MALLOC failing to allocate the buffer
increase as you impose more stringent restrictions...
R0: SRAM page number.
R1: Address in SRAM
Upon return, the Eq bit will be set if all went well.
JEQ All went well JNE Error (e.g. wrong page number or address)
R0 + R1: Source.
R2: Number of bytes to copy. If zero, nothing happens.
R3 + R4: Destination.
The source can be:
Upon return, the Eq bit will be set if all went well and reset if there was an error.
JEQ All went well JNE ErrorYou will get an error if:
BLWP @SGBLWP DATA NEWWS,PG4SEG DATA sizeR0 lsb: Page for new workspace (most significant byte ignored).
When this routine is called, the current SRAM page is placed into the most significant byte of R0 and the current worspace address is substracted from R1 (i.e. R1 now contains the differential offset between the two workspace). If you copy at least 4 bytes into the new workspace, you will be able to use R0 and R1 to return to the old workspace, using an alternative syntax:
BLWP @SGBLWP DATA NEWWS,PG4SEG DATA size + >8000R0 msb: Page for new workspace (least significant byte ignored).
Exemple:
REF MALLOC,NEWWS,PG4SEG LWPI WREGS current workspace LI R0,36 obtain address for new workspace + 2 words BLWP @SGBLWP DATA MALLOC,PG4SEG JNE ERROR BLWP @SGBLWP DATA NEWWS,PG4SEG switch to new workspace DATA 36 copying workspace + 2 data words * CLR @THIS this won't work !!! CLR @THIS(R1) access the copies SETO @THAT(R1) BLWP @SGBLWP DATA NEWWS,PG4SEG switch back to old workspace DATA >8000 don't copy anything back (although we could) CEND * Data segment DSEG WREGS BSS 32 initial workspace THIS DATA 0 variables THAT DATA 0 OTHER DATA 0 DEND |
If you elect to copy extra data words after your workspace, be aware that their address may vary according to what MALLOC returned. In the exemple above, let's say your initial workspace was at >5040 in page 0; this means that THIS was at >5060, and THAT at >5062. Now let's say that MALLOC found free space at >5068 in page 3; this means that THIS will be copied at >5088 and THAT at >508A.
Because the address of the copies is different from that of the original, you cannot just write CLR @THIS or SETO @THAT: such instructions would be hard-coded as CLR @>5062 and SETO @>5064, which are the correct addresses in SRAM page 0, but who knows what's to be found there in page 3! By using R1 as an index, you can correct the addresses and make sure the copies of THIS and THAT are properly accessed. Of course, you may copy this index to another register, less frequently used than R1.
Note that if you change workspace twice in a row, you will need to add up the offsets returned into R1 by each call to NEWWS, so that the addresses remains correct. For instance, save R1 into R7 after the first call, and add R1 to R7 for each successive call. To return to the original workspace, you will also need to save R0 msb after the first call.
R0: data to be saved
R1: data to be saved
R0: data retrieved
R1: data retrieved
NB This routine and the previous one actually call RAMCPY with preset parameters.Their main usage is to save the location of a private memory area, obtained with MALLOC. You can then retrieve this location the next time your DSR is called.
Example:
REF MYSLOT BLWP @SGBLWP call routine in another page DATA ATSLOT,PG4SEG retrieve contents of our slot DATA MYSLOT MOV R0,R0 check if empty (RAM page is never 0) JNE SK1 we already set our private memory LI R0,>0100 size of the private area we need BLWP @SGBLWP DATA MALLOC,PG4SEG obtain it: R0 = page, R1 = address JNE ERROR BLWP @TOSLOT save R0 and R1 into our slot DATA MYSLOT B *11 SK1 LI R2,>0100 copy private area (256 bytes) SETO R3 into current SRAM page LI R4,HERE at this location BLWP @SGBLWP DATA RAMPCY,PG4SEG B *11 |
BLWP @SGBLWP DATA LOCKDS,PG4SEG DATA page,datbeg,datend JOC Already called? JNE Something went wrongpage: is the page number assigned to your private data segment. This parameter may be omited, in which case LOCKDS will find an appropriate page. If you are using a page number, your segment should have the FIXPG flag set. The loader will save the page, address and size of your segment within the removal information, and make sure no other such segments conflict with yours. You can obtain the page number with PG4SEG.
LOCKDS returns with a page number in R0 (page, if it was provided) and an address (datbeg) in R1.
You must check the Eq bit to know whether the appropriate space could be allocated. This is not a given, since another DSR may have called MALLOC before yours, and be granted (part of) the space you wanted. This is, of course, more likely to happen if you specify a fixed page number than if you let LOCKDS decide on it. If you are using a page number, you may also want to check the carry bit after calling LOCKDS. It will be set if a buffer with the exact same size was reserved at the same address in the same page. Most likely, this means your DSR already called LOCKDS, but you may want to implement a flag to make sure of this.
See above for examples of how to use LOCKDS.
I am also providing an export segment in a separate file ISPEXP/O, so you can make these routines available for inter-segment calls if you so wish.
Alternatively, you may want to copy the source into one of your segment. It will need assembling, but this gives you the chance to check how things are done. To this end simply include the file ISP1161/S inside your program with a "copy" statement: COPY "DSK1.ISP1161/S". A PC text version of this file is available here: ISP1161.TXT.
In addition, here is a small demo program USBTEST.TXT, which makes use of the above routine to test the USB ports: just connect the upstream port to downstream port #1 (the bottom one) and you'll be able to verify that the host controller and the device controller can talk to each other through a USB cable. Alternatively, here is a zip file containing both the text versions and DF80 files to be transfered to your TI-99/4A.
Host Controller routines:
HCR Host Controller Read (a.k.a. HCR2) HCW Host Controller Write (a.k.a. HCW2) HCWI Host Controller Write Immediate (a.k.a. HCWI2) HCWIM Host Controller Write Immediate Multiple
ATRL ATL Read ATLW ATL write ITLR ITL Read ITLW ITL WriteDevice controller routines:
DCA Device Controller Action DCR Device Controller Read DCW Device Controller Write DCWI Device Controller Write Immediate DCWIM Device Controller Write Immediate Multiple DCWEPCF Device Controller Write EndPoint Configuration EPST EndPoint Status EPCHK EndPoint Check status image EPERR EndPoint Error EPCFR EndPoint Configuration Read EPSTAL EndPoint Stall EPUNST EndPoint Unstall EPCLR EndPoint Clear EPVAL EndPoint Validate EPR EndPoint Read EPW EndPoint Write
BLWP @HCR or BLWP @HCR2 DATA register DATA register |
This routine is used to read from a host controller register. The data read will be placed into R1 (or in R1 and R2, for 32-bit registers) after due byte swapping, so that the MSB is in R1's MSB.
HCR2 is an alias for the same routine. It can be used as a reminder, when addressing 32-bits registers. However, the number of bytes transfered is detemined by the register number, not by the name of the routine: registers under >0020 are 32-bit.
The data word register should contain a number from >0000 through >003F, indicating the register number. If the >0080 flag is present, it will be removed.
Alternatively, register can be a number from >0100 through >010F.
In which case, it indicates a workspace register (from 0 through 15) into
which the number of the host controller register is to be found.
LI R3,>0027 register number BLWP @HCR read host controller register into R1 DATA >0203 register number is in R3 |
In case you want the results to go somewhere else than into R1, you
may use the following syntax:
BLWP @HCR DATA address,register |
Here, address is a pointer to a cpu location, in the range >0200-FFEF,
into which the contents of the host controller register will be read. Alternatively,
if address is in the range >FFF0-FFFF, the data will be placed into
worspace register R0 through R15.
BLWP @HCR DATA >AC02,>0027 Place contents of register >27 into >AC02 BLWP @HCR DATA >FFF5,>0027 Ditto, but place them into R5 |
BLWP @HCW or BLWP @HCW2 DATA register DATA register |
This routine writes data from R1 into the host controller's register specified in the data word. See above for details on register. In case the register is 32-bit, R1 will supply the most significant word and R2 the least significant word. The alias HCW2 can be used as a mnemonic for 32-bit operations, but actually it's the register number that determines the number of words.
Just like HCR, there is an alternative syntax for HCW that lets you
specify an address (or a workspace register) for the source, other than
R1 and R2:
BLWP @HCW or BLWP @HCW2 DATA address,register DATA address,register |
BLWP @HCWI or BLWP @HCWI2 DATA register,data(,data) DATA register,data,data |
This routines takes the value to write into the host controller from the data word following the register number. For 32-bit registers, two data words are required. You can use the alias HCWI2 to remind yourself of this fact.
Exemple:
BLWP @HCWI store >1234 into scratch register DATA >0028,>1234 |
BLWP @HCWIM DATA register,data(,data) (DATA register,data,(data)) DATA >0000 |
This routine is usefull when you need to set a whole bunch of registers at a time, for instance during initialization. It is followed with a list of register numbers together with the data to be placed into this register. The list is terminated with a >0000 word (register 0 is read-only). Remember that 32-bit registers require two words of data!
BLWP @ATLW or BLWP @ITLW |
These routines are used to write data to the ATL (acknowledged transfer list) stack, or to the ITL (isochronous transfer list) stack currently in used.
R1 should contain a pointer to the data to be written.
R2 should contain the number of bytes to write, rounded up to
the next even number.
Either routine copies R2 into the TransferCounter register, then passes the relevant number of words to the required stack.
BLWP @ATLR or BLWP @ITLR |
These are the mirror routines from the above ones: they read back data from the ATL or ITL stack, respectively. The number of bytes to read is passed to the host controller via the TransferCounter register.
R1 should point to a buffer large enough to accomodate the data.
R2 should contain the number of bytes to read, rounded up to
the next even number.
Ok, now for the device controller...
BLWP @DCA DATA register |
This routine is used to send a command to the device controller, by passing a register number without actually passing any data to/from it. As no data is passed, R1 is not affected, and there is no alternative syntax using an address.
Register is a the number of a device controller register, from >00 to >FF. Just like with host controller routines, values in the range >0100-010F indicates that the register number is to be found in the rightmost byte of the corresponding workspace register: >0100 is R0, >0101 is R1, etc.
BLWP @DCR or BLWP @DCR DATA register DATA address,register |
This routine is similar to the HCR routine described above, except that it addresses the device controller instead. With the first syntax, the contents of the specified register will be placed into R1. With the second, they will be placed at the specified address.
Here also, if register is in the range >0100-010F, it means that the register number is to be taken from workspace register R0 through R15, respectively.
Similarly, an address in the range >FFF0 through >FFFF indicates that the target is workspace register R0 through R15.
BLWP @DCW or BLWP @DCW DATA register DATA address,register |
This routine sets a register in the device controller, taking its value from R1 or from the specified address, respectively.
BLWP @HCWI or BLWP @HCWI2 DATA register,data(,data) DATA register,data(,data) |
This routines takes the value to write into the host controller from the data word following the register number. For the 32-bit InterruptEnable register, two data words are required.
BLWP @HCWIM DATA register,data(,data) (DATA register,data,(data)) DATA >0000 |
This routine is usefull when you need to set a several registers at a time. It is followed with a list of register numbers together with the data to be placed into this register. The list is terminated with a >0000 word (register 0 is stack access). Remember that the InterruptEnable register requires two words of data!
BLWP @DCEPCF or BLWP @DCEPCF BYTE cfg,...,cfg DATA address |
This routine is used to set the configuration of the endpoints. As per the device controller design, you must always set all 16 endpoints together, in numerical order, hence there must be exactly 16 bytes of data. The first two endpoints have preset values: the first two bytes must be >C3 and >83.
The alternative syntax provides an address (which must not be >C383)
at which the 16 bytes of data are to be found.
Since most device controller operations address endpoints, I have also provided a set of endpoint-oriented routines:
BLWP @EPST DATA endpoint |
This routine reads the status of the specified enpoint into R1.
The data word endpoint should be a number between 0 and 14. However, since there are two enpoints 0 (one for input, one for output), there is an ambiguity here. Therefore, the following convention is to be used:
Alternatively, endpoint can be a number from >0100 to >010F,
which specifies the workspace register (R0 through R15) into which the
endpoint number is to be found.
In case you don't want the data to go into R1, an alternative syntax
is provided:
BLWP @EPST DATA address,endpoint |
Where address is a pointer to a cpu memory location, in the range >0200-FFEF, where the data will to placed. In case address is in the range >FFF0-FFFF, the data will be placed in workspace register R0 through R15.
Exemples:
BLWP @EPST Place status of endpoint #0-input into R1 DATA >0020 BLWP @EPST Place status of endpoint #0-output into >C840 DATA >C840,>00C0 LI R3,>0005 Specify endpoint number BLWP @EPST Place satus of endpoint #5 into R1 DATA >0103 Get endpoint number from R3 LI R10,>C840 Specify target BLWP @EPST Place status of endpoint #6 into >C840 DATA >FFFA,>0006 Get destination from R10 LI R3,>0005 Specify endpoint number LI R8,>C840 Specify target BLWP @EPST Place status of endpoint #6 into >C840 DATA >FFF8,>0103 Get destination from R8, endpoint from R3 |
BLWP @EPCHK or BLWP @EPCHK DATA endpoint DATA address,endpoint |
This routine is equivalent to EPST, except that it accessed the StatusImage register for the given endpoint. This lets you read the status without resetting the corresponding bit in the Interrupt register.
The first version reads the status into R1, the second into the specified address.
BLWP @EPERR or BLWP @EPERR DATA endpoint DATA address,endpoint |
This routine read the error register for the specified endpoint. The first version places it into R1, the second into the specified address.
BLWP @EPCFR or BLWP @EPCFR DATA endpoint DATA address,endpoint |
This routine is used to read back the configuration of an endpoint. The first version reads it into R1, the second into the specified address.
BLWP @EPSTAL DATA endpoint |
This routine stalls the specified endpoint. This is a command, so no data is transfered. Thus R1 is not affected and there is no alternative syntax using an address.
BLWP @EPUNST DATA endpoint |
This routine unstalls the specified endpoint. No data is transfered, so R1 is not affected and there is no alternative syntax using an address.
BLWP @EPCLR DATA endpoint |
This routine empties the stack for the corresponding endpoint. This is a direction-specific routine: only input endpoints should be cleared. If the output flag >00Cx is specified, the routine will do nothing (actually, only the >004x bit is checked, the >0080 bit is ignored).
No data is passed with this routine, so R1 is not affected and there is no alternative syntax using an address.
BLWP @EPVAL DATA endpoint |
This routine is used to tell the device controller that the data placed into an output endpoint may be sent to the host upon reception of the next IN packet. This is a direction-specific routine: you should never validate an endpoint programmed as input. If the input flag >002x is specified in the endpoint number, the routine will return immediately, doing nothing.
No data is passed with this routine, so R1 is not affected and there is no alternative syntax using an address.
BLWP @EPW DATA endpoint |
This routine places data into an endpoint programmed for output (i.e. to answer IN packets from the host).
R1 should contain a pointer to the data.
R2 should contrain the number of data bytes to be written.
The routine places R2 on the endpoint's stack, followed with the data bytes read from R1. It does not verify that R2 is in the legal range for this endpoint.
BLWP @EPR DATA endpoint |
This routine reads data from an input endpoint's stack into a cpu buffer.
R1 should contain a pointer a buffer large enough to accomodate
the data
R2 should contain the maximum number of bytes that can be transfered.
Upon return, R2 will contain the number of bytes in the endpoint.
The routine first reads the number of bytes waiting inside the endpoint's stack. If this number is smaller than R2, all the bytes are transfered to the buffer specified by R1 and R2 is updated to reflect the number of bytes actually transfered.
It the number of bytes on the stack is greater than R2, only the number specified in R2 will be transfered. R2 will then be updated to reflect the total number of bytes in the endpoint's stack (not counting the two size bytes).
Alternatively, you could just load the pre-assembled file SM/O after one of your own. The SmartMedia routines are part of a no-name segment in this file, which means they will be appended to the last segment to begin in your file. This way you can call these routines with BLWP from that segment, and with BLWP @SGBLWP from all other segments. If the last segment in your file is STUB (or MYSTUB), you can use direct BLWP calls from any segment using the same stub.
Finally, I am including an export segment for these routines, in the file SMEXP/O. Load this file just after SM/O and it will make the routines available to every DSR in the card. They'll have to be called with BLWP @SGBLWP though, which is slower than a direct call via BLWP.
SMR SmartMedia Read SMV SmartMedia Verify SMVB SmartMedia Verify Byte SMW SmartMedia Write SME SmartMedia Erase SMRX SmartMedia Read eXtra bytes SMWX SmartMedia Write eXtra bytes SMID SmartMedia Read card IDUsefull tips:
R0: Pointer to SmartMedia address.
R1: Pointer to a buffer in CPU memory.
R2: Number of bytes to read. This may be more than one sector:
reading will continue with the extra information bytes for the current
sector, then with the next sector, its info bytes, etc.
A SmartMedia address should consist in three words: two for the sector number, and one for the byte offset where to start reading within the sector. Normally, this will be zero, but you can elect the start reading anywhere within a sector.
SMADR DATA >0000,>0000 Sector number DATA >0000 Byte offsetThe trouble with SmartMedia cards is that some use 2 bytes for the sector number, others use 3, or even 4. This is a problem, because older cards are thrown off by extra address bytes. Therefore, you should first check the card ID (and extended ID) to determine its addressing scheme. Another way is trial and error: passing the wrong number of address bytes generally results in reading only >00 bytes.
Once you know how many bytes to use, follow these rules:
For your convenience, provision was made for the routine to treat 512 bytes/sector cards as if they had 256 bytes/sector. This is based on the fact that most cards let you write a sector in at least two chunks. To trigger this feature, make the first byte of the offset >FF. This will cause the sector number to the divided by two before it's passed to the card. The remainder of the division is used to decide wether to access the first half, or the second half of the 512-byte sector.
Example:
LI R0,SMADR LI R1,BUFFER LI R2,256 BLWP @SMR SMADR DATA >FF00,>1234 3-byte sector number DATA >0000 start at beginning of sector BUFFER BSS 256 buffer space |
This routine works just like SMR, except that it does not place the bytes it reads into the buffer. Rather, it compares them with the contents of the buffer. If all match, the routine returns with the Eq bit set, a condition which can be trapped with JEQ.
If a mismatch is detected, the routine returns with the Eq bit reset (use JNE to trap it), and R1 pointing at the first offending byte in the buffer.
Example:
LI R0,SMADR LI R1,BUFFER LI R2,>0006 BLWP @SMV JEQ OK JNE UHOH SMADR DATA >FFFF,>1234 2-byte sector number DATA >0000 start at beginning of sector BUFFER DATA >0102,>0204,>0506 data to verify |
This routine works just like SMV, but it expects all bytes to match a given value. It comes handy to check whether a sector is blank, i.e. contains only >FF bytes.
If all bytes match, the routine returns with the Eq bit set, a condition which can be trapped with JEQ. If a mismatch is detected, the routine returns with the Eq bit reset (use JNE to trap it), and R2 will contain the number of the first offending byte (counting from zero on).
Example:
LI R0,SMADR LI R1,>FFFF LI R2,>0100 BLWP @SMVB JEQ OK JNE UHOH SMADR DATA >FFFF,>1234 2-byte sector number DATA >0000 start at beginning of sector |
This routine is used to write to the SmartMedia card. Generally, it is best to write one sector at a time. It is impossible to write more than one sector, because the card won't accept more bytes than fit in a sector plus its extra information bytes. It is possible to write less than a sector, but be aware that it's not reliable to write more than twice to the same sector. So if you don't cover the whole sector with two write operations, the remaining bytes should remain untouched.
Once it is done writing, the routine performs a status check. If everything went well, it returns with the Eq bit set. If the error flag was raised in the status byte, the routine returns with the Eq bit reset. This may happened if the card is write protected, for instance. The routine will not return until the card signals that it is ready to continue.
Example:
LI R0,SMADR LI R1,BUFFER LI R2,256 BLWP @SMW JNE ERROR SMADR DATA >0012,>3456 4-byte sector number DATA >FF00 treat card as a 256 bytes/sector card BUFFER DATA >0102,>0204,etc data to write |
This routine works just like SMR, except that it reads only the extra info bytes associated with the requested sector. Cards with 256-byte sectors will have 8 extra bytes per sector, whereas 512 bytes/sector cards have 16 extra bytes. You can read more that this number, however, since reading will continue with the extra bytes of the next sector(s).
Note that this routine will never read data from the sector itself. It is thus usefull to determine the sector size: read 520 bytes with SMR, then 8 with SMRX and check wether these 8 bytes match bytes 256 through 261, or to bytes 512 through 519.
Example:
LI R0,SMADR LI R1,BUFFER LI R2,15 BLWP @SMRX SMADR DATA >FF00,>1234 3-byte sector number DATA >0001 start at second extra byte (dummy example) BUFFER BSS 16 buffer space |
This routine is used to write the extra information bytes associated with the specified sector. It is generally best to write all of them at a time, and not to exceed the maximum (although some card may accept more, I'm not sure if they get written properly). Another solution is to write the extra bytes together with the sector data, using SMW instead of SMWX.
Just like SMW, this routine performs a status check when done and returns with the Eq bit set if everything went well, and with the Eq bit reset if the status reported an error.
Example:
LI R0,SMADR LI R1,BUFFER LI R2,8 BLWP @SMWX JNE ERROR SMADR DATA >FF00,>0002 3-byte sector number DATA >0000 start from byte 0 BUFFER DATA >FFFF,>00FF,>FF01,>0203 data to write |
This routine is used to erase a block of sectors. Depending on the card (again!), there may be 16 or 32 sectors per block. The SmartMedia address should consist in two words containing the number a a sector within the block to erase. No need for a byte offset in this case.
Once done, the routine performs a status check and returns with the Eq bit set if everything went well. If an error occured (most likely, the card being protected), it returns with the Eq bit reset.
Example:
LI R0,SMADR Address pointer BLWP @SME JNE ERROR SMADR DATA >FFFF,>1234 2-byte sector number |
This routine queries the card for its ID and places it into R1. The manufacturer ID will be in the most significant byte, the product ID in the least significant byte. In addition, it also checks the extended ID code and places it into the most significant byte of R2. If the card does not support the extended ID function, R2 is most likely to contain a >00 byte, although this is not guaranteed.
ID data is usefull to identify the SmartMedia card currently inserted and decide of its characteristics:
Example:
LI R0,SMADR Address pointer BLWP @SMID SMADR DATA >FF00,>0000 3-byte sector number: sector 0 DATA >0000 byte offset should be zero too |
If the card returns an ID that you don't know, you'll have to answer the above questions by trial and error. This is easier to do if the card is blank, as there is no concern about loosing data in the process...
Number of address bytes: Try five, then four, then three with a SMVB operation on sector 0. If it reads as all >00, then you probably don't have the right number of address bytes (unless of course the card is not blank, and sector zero was filled with >00s).
Bytes per sector: Read and save 16 info bytes for sector 0 with SMRX. Write an 8-byte test string to sector 0 info area with SMWX. Read 520 bytes from sector 0 with SMR. Check if your test string appears at bytes 256-263, or at bytes 512-530. Restore 8 or 16 info bytes (depending on the sector size) with SMWX.
Sectors per block: Save the first 32 sectors with SMR (optional). Write
a test string to sector 17 with SMW. Erase sector 0 with SME. Check if
sector 17 became all >FF with SMVB, if not there are 16 sectors per block.
Restore 16 or 32 sectors with multiple calls to SMW (optional).
Next page (DSR loader and manager)